Type
Types
Alarm state reported by the sensor.
Several alarm states reported together, for periods in which the state changed more than once.
Ambient light level.
Ammonia (NH3).
Atmospheric pressure.
Type whose value is either on or off.
Breath volatile organic compound equivalent.
Carbon dioxide (CO2).
Carbon dioxide equivalent, derived from the volatile organic compounds the sensor detects.
Carbon monoxide (CO).
Type whose value is a number taken from a range.
Electrical current. See CURRENT_PRECISE for the variant that also reports negative values.
Electrical current to three decimal places. Unlike CURRENT it also reports negative values, over a narrower range.
Dew point, the temperature at which the air becomes saturated.
Differential pressure.
Distance to the nearest object in front of the sensor.
Electricity used over one measurement period. See ELECTRICITY_USAGE_ACCUMULATED for the running total.
Running total of electricity used, counted by the sensor since its counter was last set.
Complementary channel of the accumulated electricity usage.
Heat index, the apparent temperature derived from temperature and humidity.
Pressure on a high-pressure scale, for ranges beyond what ATMOSPHERIC_PRESSURE covers.
Humidity as a whole percentage. See HUMIDITY_ACCURATE for the variant with one decimal place.
Humidity to one decimal place. See HUMIDITY for the whole-percentage variant.
Hydrogen sulfide (H2S).
Air quality index. See INTERNAL_AIR_QUALITY_STATIC for the variant on a wider scale.
Air quality index on a wider scale than INTERNAL_AIR_QUALITY.
Whether a leak is detected.
Several leak states reported together, for periods in which the state changed more than once.
Methane (CH4).
Nitrogen dioxide (NO2).
Noise level.
State of the sensor's controllable output.
Several output states reported together, for periods in which the state changed more than once.
Percentage, for channels that report a proportion rather than a named quantity.
Mass concentration of particles up to 1 µm across.
Mass concentration of particles up to 10 µm across.
Mass concentration of particles up to 2.5 µm across.
Pulses counted over one measurement period. See PULSES_ACCUMULATED for the running total.
Running total of pulses counted since the sensor's counter was last set. See PULSES_ACCUMULATED_WIDE for the variant that counts far higher.
Complementary channel of the accumulated pulse count.
Running total of pulses over a far wider range than PULSES_ACCUMULATED.
Complementary channel of the wide-range accumulated pulse count.
Resistance.
RMS current measured non-invasively by a current clamp. The measurement's accuracy is Accuracy.LOW_ACCURACY when the reading exceeds the clamp's rated range and Accuracy.HIGH_ACCURACY otherwise.
Soil moisture, reported as a negative pressure, so values closer to zero mean wetter soil.
Temperature.
Voltage.
Water used over one measurement period. See WATER_USAGE_ACCUMULATED for the running total.
Running total of water used, counted by the sensor since its counter was last set.
Complementary channel of the accumulated water usage.